Analysis Of Factors Affecting Internal Quality Assurance In Blood Glucose Examination In The Laboratory Of Budhi Asih Hospital
Abstract
Internal quality assurance activities are divided into three stages, namely the pre – analytic stage, the analytic stage, and the post – analytic stage. Examination of blood glucose requires internal quality assurance. There are several potentials that affect this implementation, such as the discovery of lysis sample. The suitability of taking blood according to the Standar Operating Procedure (SOP) must be considered. The instruments used must be in good condition, pay attention to tool mantenance and carry out Quality Control (QC) to ensure the quality of precision and accuracy in the results to be issued. Observational research design with cross sectional design involving 23 Medical Laboratory Technology (MLT) officers as respondents and 38 blood glucose samples to be examined using a chemistry analyzer. Data from quentionaires and observations were analyzed by lambda correlation test with sig <0.05. Research on internal quality assurance on the criteria of human resource the results obtained 96.9%, the SOP criteria the results obtained 91.6%, the sample quality criteria the results obtained 90.3%, and the QC criteria the results obtained 100%. The results of the lambda correlation test on four variables showed a correaltion, with the results of HR 0.008, SOP 0.016, sample quality 0.009, QC 0.016. all of the criteria for internal quality assurance are in the good category, and all of them show that there is a relation with internal quality assurance.
Full Text:
PDFReferences
Amalia, P., Kurniawan, E., Rahayu, I. G., & Noviar, G. (2019). Analisis Faktor-Faktor Kepatuhan Penerapan Standar Operasional Prosedur Pengambilan Darah Vena. Jurnal Riset Kesehatan Poltekkes Depkes Bandung, 11(2), 211. https://doi.org/10.34011/juriskesbdg.v11i2.751
Amir, S. M. J., Wungouw, H., & Pangemanan, D. (2015). Kadar glukosa darah sewaktu pada pasien diabetes melitus tipe 2 di Puskesmas Bahu kota Manado. EBiomedik, 3(1).
Ariyani, L., Siagian, L. R. D., Yusran, D. I., & Yulianti, F. (2019). Pengaruh Indek Hemolisis Terhadap Peningkatan Kadar Serum Glutamate Oxaloacetat Transaminase (SGOT). Jurnal Kesehatan, 5(1), 42–50.
Hanafi, A., & Misnaimah, M. (2019). Faktor Yang Berhubungan Dengan Kinerja Petugas Dalam Menerapkan Standar Operasional Prosedur Di Upt Laboratorium Kesehatan Dan Lingkungan Dinas Kesehatan Provinsi Riau. Health Care : Jurnal Kesehatan, 8(1), 1–10. https://doi.org/10.36763/healthcare.v8i1.35
Kemenkes R.I. (2013). Peraturan Menteri Kesehatan Republik Indonesia Nomor 43 Tahun 2013 Tentang Penyelenggaraan Laboratorium Yang Baik
Kemenkes R.I. (2015). Menteri Kesehatan Republik Indonesia Nomor 42 Tahun 2015.
Kitchen, S., Olson, J. D., & Preston, F. E. (2013). Quality in laboratory hemostasis and thrombosis. John Wiley & Sons.
Nugrahena, N. P., Sudarsono, T. A., & Wijayanti, L. (2021). Pengaruh Hemolisis Terhadap Nilai Trombosit Dengan Menggunakan Metode Direct Counting. Jurnal Analis Medika Biosains (JAMBS), 8(2), 108. https://doi.org/10.32807/jambs.v8i2.228
Permenkes. (2010). Peraturan Menteri Kesehatan Republik Indonesia No 411/MENKES/PER/III/2010 tentang Laboratorium Klinik. In Pusat Komunikasi Publik Departemen Kesehatan (p. 210).
Rizky, V., & Wulan, W. S. (2019). Pengaruh Waktu Penanganan Pemeriksaan Terhadap Kadar SGPT Pada Serum dan Plasma EDTA. Jurnal Analis Kesehatan SAINS, 8(2), 777–781.
Saurav Patra, M., Mukherjee, B., & Das, A. K. (2013). Pre-analytical errors in the clinical laboratory and how to minimize them. Int. J. Bioassays, 2(3), 551–553.
Syauqiah, N. R., Hartiti, T., & Faruq, Z. H. (2018). Studi Kualitas Pemantapan Mutu Internal Pra Analitik Laboratorium Rumah Sakit Roemani Muhammadiyah Semarang.
Tuntun, M., Sriwulan, W., Doni, S., & Nuryati, A. (2018). Kendali Mutu (1st ed., p. 529).
Wibowo, I. Y. (2021). Faktor - Faktor Yang Mempengaruhi Kepatuhan Penerapan SOP APD Petugas Laboratorium Rumah Sakit X. Jurnal Sains Dan Teknologi Laboratorium Medik, 7(2), 24–23.
DOI: https://doi.org/10.30602/jlk.v6i1.1064
Article Metrics
Refbacks
- There are currently no refbacks.
Copyright (c) 2022 Jurnal Laboratorium Khatulistiwa
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.